Warm Roof Insulation
So what is warm flat roof construction?
A warm flat roof is formed by placing a layer of insulation over the top of the roof structure. Due to the insulation being over the top of the roof, the timber structure beneath is warm, which is why the term ‘Warm Roof’ is formed.
Steve from London Flat Roofing explains how warm flat roof construction works in this excellent short video:
Building Regulations
When 50% or more of the roof’s waterproofing layer is removed and replaced this is called refurbishment. Part L of the Building Regulations states that the thermal efficiency of a refurbished roof be brought up to current standard if it doesn’t meet a minimum thermal performance. If your roof insulation doesn’t meet the minimum standards, it has to be upgraded. However, this does not apply if you are repairing your flat roof by overlaying with a new waterproof layer.
These factors can trigger part L of the building regulations document:
1. If you strip the covering of an old flat roof, you automatically trigger part L of the building regulations document.
2. If your current insulation is poor, then you trigger part L of the building regulations document.
3. If you are undergoing a domestic or a commercial rebuild, it must comply with part L of the building regulations document.
The aim of the revised and updated documents are to ensure buildings are constructed or modified to provide better energy efficiency and tackle the problem. As climate change research continues, the new goals of the documents are to reduce CO2 emissions by 31% on new build dwellings and 27% on other buildings, as well as a new emphasis on low carbon heating systems.
You can find a link to the building regulations document here.
What else?
In a warm flat roof construction, the insulation is positioned above the structural deck and no ventilation is required.
Throughout the course of the year the roof deck and all below it is kept at a temperature close to that of the inside of the building, therefore the roof structure is protected from extremes of hot and cold, lessening the potential for damage caused by thermal movement.
A warm deck also provides added protection from the dangers of condensation as the structure is kept warm, at a temperature above dewpoint, by the insulation above it. Therefore water vapour which enters the roof structure from the room below will not have a cold surface on which to condense. NHBC recommend that this type of roof be considered as the standard form of construction.